Snapease wall sleeve features and.
Ptac wall sleeve installation.
Wall is shown in table 1.
The kit installation instructions are included with the accessory kits.
Standard steel wall cases are 42 w 16 h 13 3 4 d.
If the distance between wall sleeve and wall will be at or near the minimum clearance distance mount these kits on the sleeve before installing the sleeve in the wall.
Pay attention to how much of the sleeve shows on the inside of the room.
Insure that the unit is only installed in a wall structurally adequate to support the unit including the sleeve chassis and accessories.
Sleeve must be tight against the bottom shim and fully bedded into sealant.
16 6 410 m wall receptacle within 58 from bottom right side corner on 208.
Place the unit into the sleeve and screw it in place.
Summary the above is the basic steps to install a through the wall air conditioner sometimes call a window wall slide out air conditioner.
Wall sleeve installation 920 087 04 8 05 wall sleeve installation instructions pdxws note.
The wall sleeve be installed a minimum of 36 from the ceiling.
If the sleeve projects more than 8 into the room a sub base or other means of support must be used.
Install a backer rod if necessary to maintain a consistent gap between the louver frame flange and ptac sleeve across the top and down both sides.
Wall case should be sealed caulked to the inside wall on all four 4 sides.
The sub base sits under the unit on the room side supporting the weight and keeping the unit level.
Installation of a thru the wall.
It is the insta oohu vuhvsrqvlelolw to ensure there is adequate drainage for the ptac.
Wall case must be sealed caulked to outside wall on all four 4 sides.
Caulk along the outside sleeve edges to prevent leaks.
If you ve got more than a few inches showing then you need to install a sub base.
16 24 28 and 31 deep cases are available for thicker walls.
Install the sleeve and secure with mounting fasteners.
Every scenario will be different with wall type and power always changing.
To ensure proper airflow and filter removal it is recom mended installation of the wall sleeve be a minimum of 36 from the ceiling.
Air conditioner unit is centered in wall sleeve and sealed with foam pads to prevent air leakage.
How much wall sleeve should show on the inside the wall sleeve houses the ptac chassis.
Unit has a slight rearward slope within wall sleeve for proper drainage use tapered foam blocks.
Wall sleeve is secure and properly sealed to the wall.
Apply sealant to completely fill this pocket.
All wall and window wall installations must provide for proper drainage.
This is an animation i created to show how correct installation of a ptac unit can keep water intrusion from occurring.
Keys to proper installation.
Inches mm inches mm inches mm wall sleeve only 3 75 0 0 0 0 subbase kit 3 75 3 1 4 85 2 3 4 70.
Power it on and test it.